Lenses
for RGB Prisms
Specifications
- Compensated for use with
prisms
- Corrected for 430-700 nm
- Fixed magnification
|
Options
Available
- Motorized iris and focus
- Canon, Nikon mounts
|
|
|
Type No.
|
F. L.
(mm)
|
Image
Diag. (mm)
|
Obj. Size
(mm)
|
FOV
Ang. (
o )
|
Min. WD
(mm)
|
F/#
|
Dist. (%)
|
Vign. (%)
|
Prism
Thick. (mm)*
|
CA (µm)
|
|
0397
|
22
|
14.5
|
210
|
37
|
270
|
1.4
|
<3
|
<10
|
38
|
<5
|
|
1497
|
14
|
7.2
|
150
|
29
|
233
|
1.4
|
<2
|
<15
|
38
|
<4
|
|
3897
|
15
|
14.5
|
300
|
50
|
270
|
1.4
|
<3
|
<10
|
38
|
<5
|
|
B9810
|
30
|
14.5
|
130
|
28
|
180
|
2
|
<2
|
<10
|
50
|
<5
|
|
B9822
|
39
|
28.7
|
700
|
40
|
850
|
2
|
<2.5
|
<25
|
38
|
<3
|
|
F2
Family – 60% modulation at 40 lp/mm, locking
motorized focus standard
|
|
C0010
|
48
|
28.7
|
150
|
--
|
180
|
2.5
|
<2.5
|
<15
|
34
|
1.0
|
|
C0011
|
50
|
28.7
|
300
|
--
|
450
|
2.5
|
<2.5
|
<15
|
34
|
1.1
|
|
C0012
|
48
|
28.7
|
500
|
--
|
744
|
2.3
|
<2.5
|
<15
|
34
|
1.5
|
|
C0013
|
47
|
28.7
|
700
|
--
|
1041
|
2.3
|
<2.5
|
<15
|
34
|
1.1
|
|
C0014
|
46
|
28.7
|
1000
|
--
|
1490
|
2.2
|
<2.5
|
<15
|
34
|
1.5
|
|
C0042
|
49
|
28.7
|
400
|
--
|
580
|
2.4
|
<2.5
|
<15
|
34
|
1.15
|
|
C0043
|
47
|
28.7
|
600
|
--
|
907
|
2.3
|
<2.5
|
<15
|
34
|
1.3
|
|
F/4
Family – 50% modulation at 50 lp/mm, motorized focus
standard
|
|
C0047
|
56
|
28.7
|
150
|
--
|
260
|
4
|
<2.5
|
<15
|
--
|
5.00
|
|
C0048
|
52
|
28.7
|
300
|
--
|
600
|
4
|
<2.5
|
<15
|
--
|
5.80
|
|
C0049
|
52
|
28.7
|
400
|
--
|
800
|
4
|
<2.5
|
<15
|
--
|
5.30
|
|
C0050
|
51
|
28.7
|
500
|
--
|
1000
|
4
|
<2.5
|
<15
|
--
|
5.25
|
|
C0051
|
50
|
28.7
|
600
|
--
|
1200
|
4
|
<2.5
|
<15
|
--
|
5.30
|
|
C0052
|
50
|
28.7
|
700
|
--
|
1400
|
4
|
<2.5
|
<15
|
--
|
5.10
|
|
C0053
|
50
|
28.7
|
1000
|
--
|
1900
|
4
|
<2.5
|
<15
|
--
|
5.50
|
* Equivalent in air
|
|
RGB Lens Gallery |
 |
 |
 |
Type 0397
22 mm / f/1.4 |
Type B9822
39 mm / f/2 |
F/2 Family
All types |
Lenses
for Visible-NIR Prisms
In these lenses Optec extended the
apochromatic correction of the RGB lens families out to 950 nm so they
may be used across the entire response band of silicon detectors. They
are suitable for us with 2, 3 and 4-channel prisms up to the maximum
rated glass thickness. |

Type 3795 – 42 mm, f/2.8 |
- Corrected for
430-950 nm
- 78 mm prism
air equivalent
- 43 mm image
diameter
- <5 µm
chromatic aberration
- 80%
transmission, A/R coated for <0.4%
- 54 degree FOV,
infinity focus
- Distortion
<10%, Vignetting <30%
- Modulation
minimum 60% at 40 lp/mm
- Motorized
focus and iris available
|

Type B9810 – 30 mm, f/2 |
- Corrected for
430-950 nm
- 50 mm prism
air equivalent
- 14.5 mm image
diameter
- <5 µm
chromatic aberration
- 80%
transmission, A/R coated for <0.5%
- 28 degree FOV,
180 mm working distance
- Distortion
<2%, Vignetting <10%
- Modulation
minimum 80% at 40 lp/mm
- Motorized
focus and iris available
|
|
|